UV Drain bottle
Jump to navigation
Jump to search
IMPORTANT Tilting the drain bottle too much to the point that it comes free of the bottom plate may lead to discharged fluid spilling out
The "EMPTY DRAIN BOTTLE" message appears when a certain amount of discharged fluid has collected in the bottle. To dispose of the discharged fluid follow the following steps:
- Press [ENTER] when the message appears
- Open the panel cover:
- Remove the screw on the top of the panel cover
- Tilt the panel cover forward slightly,
- Pull out the panel cover in the direction indicated by the arrow
- Remove the drain bottle and discard the discharged fluid:
- Push down on the opening of the drain bottle
- While pushing down on the opening, slide the bottle to the front, ensuring that the bottle stays on the bottom plate
- Detach the drain bottle
- Empty the drain bottle in the designated "Ink waste" container on the bottom shelf in the chemical close
- Place the drain bottle back into the machine, making sure to push it all the way down and shove if all the way to the back
- Place the panel cover back on the machine, making sure to tilt the panel cover slightly forward again
- Put the screw back onto the machine